Difference between revisions of "Kanalog Hardware Info"

From Dynomotion

Jump to: navigation, search
(Added inital setup)
(Testing Analog Amplifiers)
Line 34: Line 34:
 
# check that the DACs can command the Amplifier to control motor speed.  Test Console commands like DAC0=200  (with the axis disabled)
 
# check that the DACs can command the Amplifier to control motor speed.  Test Console commands like DAC0=200  (with the axis disabled)
 
# Enable the Servo using the Step Response Screen.  Zero, Enable
 
# Enable the Servo using the Step Response Screen.  Zero, Enable
 +
 +
 +
 +
==Testing Analog Amplifiers==
 +
One way to perform a basic test of an Analog Amplifier to see if it is working and likely capable of being driven by a Kanalog DAC Output is to apply a small voltage to the input to see if the motor drives.  A 1.5V battery in series with a 1K Ohm resistor is one possible voltage source.  The 1K Ohm resistor should limit the current in case a mistake is made.  When applied the motor should drive at a controlled 15% (Speed if the drive is in Velocity mode, or torque if in torque mode).  Reversing the battery should reverse the motor direction.

Revision as of 18:14, 14 October 2015

Kanalog adds Analog and other I/O to KFLOP

KanalogKflop350.png


Specification

Kanalog Hardware/Connectors

BlockDiagram Board Layout
Kanalog Use and Settings  

Relay Drivers / Grounding

The 8 Relay drivers are open collector type (switch to GND) capable of switching loads up to 1Amp at up 24V.  They share a common GND with Kanalog (are not isolated).  The outputs on Kanalog are not guaranteed to power up off until after KFLOP has booted.  The additional SWE relay driver should be used as a master enable to avoid momentary power up issues.  SWE is guaranteed to remain off until after all the Kanalog Outputs have been initialized off.

Kanalog has a single GND common to KFLOP, control logic, relay drivers, and Analog signals.  The GND should normally be isolated from Earth GND to avoid ground loops and injecting earth GND noise into Kanalog/KFLOP DC GND.  Standoff mounting holes are completely isolated with the exception of the GND lug holes marked "GND".

The Opto Inputs and Outputs are fully isolated.

Initial Setup/Testing for Analog Amplifiers

There is a starting configuration for KFLOP+Kanalog called KanalogInitialPID.mot in the \KMotion\Motors folder.  Load it into an axis channel from the KMotion Configuration Screen.
The basic first steps are to verify the hardware:
  1. check the encoder counts correctly
  2. check that the DACs can command the Amplifier to control motor speed.  Test Console commands like DAC0=200  (with the axis disabled)
  3. Enable the Servo using the Step Response Screen.  Zero, Enable


Testing Analog Amplifiers

One way to perform a basic test of an Analog Amplifier to see if it is working and likely capable of being driven by a Kanalog DAC Output is to apply a small voltage to the input to see if the motor drives.  A 1.5V battery in series with a 1K Ohm resistor is one possible voltage source.  The 1K Ohm resistor should limit the current in case a mistake is made.  When applied the motor should drive at a controlled 15% (Speed if the drive is in Velocity mode, or torque if in torque mode).  Reversing the battery should reverse the motor direction.